The following plugin provides functionality available through Pipeline-compatible steps. Read more about how to integrate steps into your Pipeline in the Steps section of the Pipeline Syntax page.
For a list of other such plugins, see the Pipeline Steps Reference page.
BMC DevOps for CFA Plugin
: BMC AMI DevOps for Application Checkpoint Analysisserver : String
port : String
user : String
jclContent : String
chkfreq : String
jobCard : String
acctno : String
thresh : String
sortby : String
pswd : String
prilog : String
cfaLoadLibs
lib : String
cfaSldsLibs
sldsname : String
sldsver : String
sldsunit : String
sldsvolser : String
cfaDliLibs
dliname : String
dliver : String
dliunit : String
dlivolser : String
cfaJobnames
jobname : String
cfaReconSets
recon1 : String
recon2 : String
recon3 : String
goodRC : String
bmcSlds : boolean
You can use the SLDS keyword on the ANALYZE control statement to identify explicitly an input log data set to use as input to the analysis process. SLDS=(dataSetName,Rvr, unit,volser) If you want CFA to read multiple log data sets, specify multiple instances of the SLDS keyword.
Example: IMSA is an IMS version 14.1 system and creates generations of SLDSs that use the naming convention imsid.SLDS.Ddate.GENnnn. The SLDSs are cataloged. To analyze log records that IMSA wrote to generations 10 through 12 on March 29, 2015, specify the following keywords on the ANALYZE control statement:
SLDS=(IMSA.SLDS.D2008088.GEN010, R141)
SLDS=(IMSA.SLDS.D2008088.GEN011, R141)
SLDS=(IMSA.SLDS.D2008088.GEN012, R141)
bmcDb2log : boolean
You can use the DB2LOG keyword on the ANALYZE control statement to identify a DB2 log data set that was created by a DB2 subsystem.
Note: If you specify the DB2LOG keyword, do not specify the DB2BSDS keyword.
db2log : String
db2bsds : String
limit : String
skip : String
maxlogs : String
If you specify a value from 1 through 999, Log Analyzer stops reading log data sets after it reaches the specified number of log data sets. If Log Analyzer does not read other log data sets because the specified limit was reached, a warning message indicates the number of log data sets that were not read.
If you want Log Analyzer to read all log data sets, specify MAXLOGS=999.
The default is MAXLOGS=100 (Log Analyzer reads a maximum of 100 log data sets).
bmcDb2bsds : boolean
You can use the DB2BSDS keyword on the ANALYZE control statement to identify a DB2 bootstrap data set (BSDS).
Specify the fully qualified data set name. This name should refer to a VSAM key-sequenced data set (KSDS).
Do not specify the name of a BSDS archive copy, which is not a VSAM KSDS. BSDS cannot be a TAPE dataset.
Note:
bmcLimit : boolean
You can use the LIMIT keyword (or the LIM abbreviation) on the ANALYZE control statement to set a limit on the number (1 through 9999999999) of log records to process from an input log data set.
Note:
bmcSkip : boolean
You can use the SKIP keyword on the ANALYZE control statement to specify a number (1 through 9999999999) of log records in an input log data set to skip before CFA begins to process records.
The default is SKIP=0, which skips no records.
Note:
If you specify the SKIP keyword, you must specify one SLDS keyword. The SLDS keyword is required, and multiple SLDS keywords are not allowed.
bmcActiveOlds : boolean
bmcImsid : boolean
You can use the IMSID keyword on the ANALYZE control statement to specify one or more IMSIDs.
If you do not check this option,then the the default IMSID=ALL will be taken and all log records for all IMS systems that are associated with the input RECON data set (or data sets) will be considered.
Note:
If you specify the SLDS keyword, you cannot specify the IMSID keyword. The IMSID keyword applies only if CFA is reading RECON data sets to determine which log data sets to process.
bmcDlilog : boolean
You can use the DLILOG keyword on the ANALYZE control statement to identify explicitly an input dli log data set to use as input to the analysis process.
Specify the keyword values as follows:
DLILOG=(dataSetName,Rnn)
DLILOG=(dataSetName,Rvr,unit,volser)
Notes:
bmcMaxlogs : boolean
Use this keyword when you are using implicit specification of log data sets and Log Analyzer is reading RECON data sets to determine which log data sets to process. In this case, the number of log data sets to be processed is unknown. The MAXLOGS keyword can help you prevent a problem that could result from processing an excessive number of log data sets.
The MAXLOGS keyword works differently, depending on how you specify the value:
bmcJobname : boolean
You can use the JOBNAME keyword on the ANALYZE control statement to specify one or more JOBNAMEs. Each JOBNAME (one to eight characters) identifies a Job name. Log Analyzer uses the JOBNAME when determining which dli log data sets to use as input.
To process log records for all Job names that are associated with the input RECON data set (or data sets), specify JOBNAME=ALL.
If you omit the JOBNAME sub-keyword, Log Analyzer uses the default value ALL.
Note:
cfaImsids
imsid : String
bmcRecon : boolean
You can use the RECON keyword on the ANALYZE control statement to specify the names of a set of RECON data sets to examine during the CFA job.
If you want CFA to examine multiple sets of RECON data sets, you must specify each set with a separate RECON keyword.
If you specify the RECON keyword, your user ID must have Security Access Facility (SAF) READ access to the RECON data sets.
You can specify from one to three data set names. One of the specified data set names must be designated as COPY1 by IMS.
Example:
The RECON data sets for the IMSA system are named IMSA.RECON1 and IMSA.RECON2, and the RECON data sets for the IMSB system are named IMSB.RECON1 and IMSB.RECON2. To examine IMSA and IMSB RECON data sets in the CFA job, specify the following keywords on the ANALYZE control statement:
RECON=(IMSA.RECON1, IMSA.RECON2)
RECON=(IMSB.RECON1, IMSB.RECON2)
Note:
If you specify the RECON keyword, you must specify the INTERVAL control statement with a START time value and a STOP time value.
bmcTimezone : boolean
bmcStartInterval : boolean
You can use the START keyword on the INTERVAL control statement for the following purposes:
bmcStopInterval : boolean
You can use the STOP keyword on the INTERVAL control statement for the following purposes:
� Specify the end of a range of log records to identify as candidates for the record selection process
� Control the end of range of log data sets to allocate from RECON information
� Reduce the overall number of log records that are selected from input SLDS or extract files
start
value : String
startDate : String
startlogSeq : String
stop
value : String
stopDate : String
stoplogSeq : String
tz
value : String
timezoneoffset : String
jobInclude : String
jobExclude : String
psbInclude : String
psbExclude : String
maxlogsRc : String
If you specify a value from 1 through 999 followed by literal R and a return code (08 through 99), Log Analyzer issues the specified return code and terminates the job step if more than the specified number of log data sets would be read. Log Analyzer issues the return code at the conclusion of the RECON analysis phase without reading any input log data sets.
Example:
If you want Log Analyzer to issue return code 16 and terminate the job step if more than 10 log data sets would be read, specify the following keyword on the ANALYZE control statement:
MAXLOGS=(10,R16)
maxlogsAbend : String
If you specify a value from 1 through 999 followed by an abend code (1 through 4095), Log Analyzer issues a user abend code and terminates the job step if more than the specified number of log data sets would be read. Log Analyzer issues the user abend at the conclusion of the RECON analysis phase without reading any input log data sets.
Example:
If you want Log Analyzer to issue a user abend, with abend code U4000, if more than 120 log data sets would be read, specify the following keyword on the ANALYZE control statement:
MAXLOGS=(120,4000)
bmcJobInc : boolean
bmcJobExc : boolean
bmcPsbInc : boolean
bmcPsbExc : boolean
bmcChkfreq : boolean
bmcThresh : boolean
bmcPrilog : boolean
You can use the PRILOG keyword on the ANALYZE control statement to specify the logs type associated with the input RECON data set (or data sets) to use as input to the analysis process.
You can select one of the following values:
bmcAppcheck : boolean
bmcAll : boolean
bmcLsec : boolean
chkfreqval : String
bmcPlanInc : boolean
planInclude : String
bmcPlanExc : boolean
planExclude : String
bmcSortby : boolean
bmcCsv : boolean
bmcFullreport : boolean
Please submit your feedback about this page through this quick form.
Alternatively, if you don't wish to complete the quick form, you can simply indicate if you found this page helpful?
See existing feedback here.